Search Results (1030 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-36426 1 Targit 1 Decision Suite 23.2.15007.0 2026-04-15 7.5 High
In TARGIT Decision Suite 23.2.15007.0 before Autumn 2023, the session token is part of the URL and may be sent in a cleartext HTTP session.
CVE-2025-8863 1 Yugabyte 1 Yugabytedb 2026-04-15 3.7 Low
YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission
CVE-2025-6180 1 Strongdm 1 Sdm-cli 2026-04-15 N/A
The StrongDM Client insufficiently protected a pre-authentication token. Attackers could exploit this to intercept and reuse the token, potentially redeeming valid authentication credentials through a race condition.
CVE-2025-61738 1 Johnsoncontrols 5 Iq Panels2, Iq Panels2+, Iqhub and 2 more 2026-04-15 N/A
Under certain circumstances, attacker can capture the network key, read or write encrypted packets on the PowerG network.
CVE-2025-47419 2026-04-15 N/A
Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic. The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords. This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
CVE-2025-44251 2026-04-15 7.5 High
Ecovacs Deebot T10 1.7.2 transmits Wi-Fi credentials in cleartext during the pairing process.
CVE-2025-2818 2026-04-15 3.5 Low
A vulnerability was reported in version 1.0 of the Bluetooth Transmission Alliance protocol adopted by Motorola Smart Connect Android Application that could allow a nearby attacker within the Bluetooth interaction range to intercept files when transferred to a device not paired in Smart Connect.
CVE-2025-25728 2026-04-15 6.5 Medium
Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to send communications to the update API in plaintext, allowing attackers to access sensitive information via a man-in-the-middle attack.
CVE-2024-5631 2026-04-15 N/A
Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the video stream.  The credentials are being sent when a user decides to change his password in router's portal.
CVE-2024-45102 1 Lenovo 1 Xclarity Administrator 2026-04-15 6.8 Medium
A privilege escalation vulnerability was discovered that could allow a valid, authenticated LXCA user to escalate their permissions for a connected XCC instance when using LXCA as a Single Sign On (SSO) provider for XCC instances.
CVE-2024-45101 1 Lenovo 1 Xclarity Administrator 2026-04-15 6.8 Medium
A privilege escalation vulnerability was discovered when Single Sign On (SSO) is enabled that could allow an attacker to intercept a valid, authenticated LXCA user’s XCC session if they can convince the user to click on a specially crafted URL.
CVE-2024-0066 1 Axis 3 Axis Os, Axis Os 2020, Axis Os 2022 2026-04-15 5.3 Medium
Johan Fagerström, member of the AXIS OS Bug Bounty Program, has found that a O3C feature may expose sensitive traffic between the client (Axis device) and (O3C) server. If O3C is not being used this flaw does not apply. Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution.
CVE-2020-36914 1 Qihang Media 1 Web Digital Signage 2026-04-15 7.5 High
QiHang Media Web Digital Signage 3.0.9 contains a sensitive information disclosure vulnerability that allows remote attackers to intercept user authentication credentials through cleartext cookie transmission. Attackers can perform man-in-the-middle attacks to capture and potentially misuse stored authentication credentials transmitted in an insecure manner.
CVE-2025-26654 2026-04-15 6.8 Medium
SAP Commerce Cloud (Public Cloud) does not allow to disable unencrypted HTTP (port 80) entirely, but instead allows a redirect from port 80 to 443 (HTTPS). As a result, Commerce normally communicates securely over HTTPS. However, the confidentiality and integrity of data sent on the first request before the redirect may be impacted if the client is configured to use HTTP and sends confidential data on the first request before the redirect.
CVE-2017-20200 2026-04-15 3.7 Low
A vulnerability has been found in Coinomi up to 1.7.6. This issue affects some unknown processing. Such manipulation leads to cleartext transmission of sensitive information. The attack can be launched remotely. This attack is characterized by high complexity. The exploitability is assessed as difficult. The exploit has been disclosed to the public and may be used. The vendor replied with: "(...) there isn't any security implication associated with your findings."
CVE-2024-41124 2026-04-15 6.3 Medium
Puncia is the Official CLI utility for Subdomain Center & Exploit Observer. `API_URLS` is utilizing HTTP instead of HTTPS for communication that can lead to issues like Eavesdropping, Data Tampering, Unauthorized Data Access & MITM Attacks. This issue has been addressed in release version 0.21 by using https rather than http connections. All users are advised to upgrade. There is no known workarounds for this vulnerability.
CVE-2024-36558 2026-04-15 7.5 High
Forever KidsWatch Call Me KW-50 R36_YDR_A3PW_GM7S_V1.0_2019_07_15_16.19.24_cob_h suffers from Cleartext Transmission of Sensitive Information due to lack of encryption in device-server communication.
CVE-2022-32510 1 Nuki 1 Bridge 2026-04-15 7.1 High
An issue was discovered on certain Nuki Home Solutions devices. The HTTP API exposed by a Bridge used an unencrypted channel to provide an administrative interface. A token can be easily eavesdropped by a malicious actor to impersonate a legitimate user and gain access to the full set of API endpoints. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2.
CVE-2020-36917 2026-04-15 7.5 High
iDS6 DSSPro Digital Signage System 6.2 contains a sensitive information disclosure vulnerability that allows remote attackers to intercept authentication credentials through cleartext cookie transmission. Attackers can exploit the autoSave feature to capture user passwords during man-in-the-middle attacks on HTTP communications.
CVE-2024-1657 1 Redhat 3 Ansible Automation Platform, Ansible Automation Platform Developer, Ansible Automation Platform Inside 2026-04-15 8.1 High
A flaw was found in the ansible automation platform. An insecure WebSocket connection was being used in installation from the Ansible rulebook EDA server. An attacker that has access to any machine in the CIDR block could download all rulebook data from the WebSocket, resulting in loss of confidentiality and integrity of the system.